beautypg.com

3 meter size table, 4 factors for volume, 5 factors for time – KROHNE IFC 010 Converter HART User Manual

Page 29

background image

HARTÆ Communications Protocol

IFC010 Command Specification Rev: 1.0

Release Date: 29 May 1997

© 1997 KROHNE Mefltechnik D-47058 Duisburg

Page

29

247 user

defined

9.3

Meter Size Table

Index

Diameter

mm

inch

0

10

3/8

1

15

1/2

2

20

3/4

3

25

1

4

32

1 1/4

5

40

1 1/2

6

50

2

7

65

2 1/2

8

80

3

9

100

4

10

125

5

11

150

6

12

200

8

13

250

10

14

300

12

15

400

16

16

500

20

17

600

24

18

700

28

19

800

32

20

900

36

21

1000

40

NOTE: For Ecoflux implementation only the first 12 Table entries are possible (10 - 150 mm), while for Aquaflux any
Table entry is allowable.

9.4

Factors For Volume

Unit

Factor

Cubic meters

1.0

Hectoliters

10.0

Deciliters

10 000.0

Centiliters

100 000.0

Milliliters

1 000 000.0

US gallons

264.172

Millions US gallons

0.000 264 172

Imperial gallons

219.969

Mega imperial gallons

0.000 219 969

Cubic feet

35.3146

Cubic inches

61 024.0

US barrels liquid

8.363 64

US barrels ounces

33 813.5

9.5

Factors For Time

Unit

Factor

Seconds

1

Minutes

60

Hours

3 600

Day