beautypg.com

8 command #137 reset totalizers, 9 command #138 read analog output function – KROHNE IFC 010 Converter HART User Manual

Page 17

background image

HARTÆ Communications Protocol

IFC010 Command Specification Rev: 1.0

Release Date: 29 May 1997

© 1997 KROHNE Mefltechnik D-47058 Duisburg

Page

17

0

No Command-Specific Errors

1-4

Undefined

5

Too Few Data Bytes Received

6

Undefined

7

In Write Protect Mode

8

Update Failure

9-127

Undefined

8.8

Command #137

Reset Totalizers

Clears (sets to zero) both totalizers.

REQUEST DATA BYTES

NONE

RESPONSE DATA BYTES

NONE

COMMAND-SPECIFIC RESPONSE CODES

0

No Command-Specific Errors

1-6

Undefined

7

In Write Protect Mode

8

Update Failure

9-15

Undefined

16

Access Restricted

17-127

Undefined

8.9

Command #138

Read Analog Output Function

Reads the function of current/pulse output.

REQUEST DATA BYTES

#0
ANALOG
OUTPUT
NUMBER
CODE

RESPONSE DATA BYTES

#0

#1

ANALOG

ANALOG

OUTPUT

OUTPUT

NUMBER

FUNCTION

CODE

CODE

Data Byte #0

Analog Output Number Code, equals м1о for current output and м2о - for p ulse output

Data Byte #1

Analog Output Function Code:
0 - Off,
1 - 1 Dir, output traces flowrate measurements only in one direction,
3 - 2 Dir, output traces flowrate measurements in both directions.

COMMAND-SPECIFIC RESPONSE CODES

0

No Command-Specific Errors

1

Undefined

2

Invalid Selection