Transmitter-specific tables, 1 primary variable unit codes, 2 totalizer unit codes – KROHNE IFC 010 Converter HART User Manual

Page 28

background image

HARTÆ Communications Protocol

IFC010 Command Specification Rev: 1.0

Release Date: 29 May 1997

© 1997 KROHNE Mefltechnik D-47058 Duisburg

Page

28

RESPONSE DATA BYTES

#0

#1

RS485

RS485

CONTROL

DEVICE

BYTE

ADDRESS

Data Byte #0

Bit-mapped control variable:

Bit #7..Bit #4 - RS485 baudrate:
0000 - м1200о
0001 - м2400о
0010 - м4800о
0011 - м9600о
0100 - м19200о

Bit #3..Bit #0 - RS485 mode:
0000 - ìOffî
0100 - ìKROHNE Protocolî

Data Byte #1

The device bus address in RS485-based network, valid settings: 0..249.

COMMAND-SPECIFIC RESPONSE CODES

0

No Command-Specific Errors

1-4

Undefined

5

Too Few Data Bytes Received

6-127

Undefined

9. Transmitter-Specific Tables

Refer to the Common Tables Document for all references in this section to ìSubset of Tableî.

9.1

Primary Variable Unit Codes

Subset of Table II, Unit Codes

24

liters/sec

17

liters/min

138

liters/hour

28

cubic meters/sec

131

cubic meters/min

19

cubic meters/hour

22

gallons/sec

16

gallons/min

136

gallons/hour

248

user defined

9.2

Totalizer Unit Codes

Subset of Table II, Unit Codes

40

gallons

41

liters

43

cubic meters