Part D Technical data, measuring principle, block diagram

10.

Technical data

10.1

Versions, measuring ranges, accuracies

Versions

Compact systems (K)
UFM 400 K
UFM 500 K
UFM 500 K-EEx

Signal converter (C)
UFC 400
UFC 500
UFC 500-EEx

Local display
no
yes
yes

Primary head (S)
UFS 500
UFS 500
UFS 500

Remote systems (F)
UFM 400 F
UFM 500 F
UFM 500 F-EEx

UFC 400
UFC 500
UFC 500 F-EEx

no
yes
yes

UFS 500 F
UFS 500 F
UFS 500 F-EEx

Measuring ranges

Full-scale range Q

100%

UFM 400: factory setting
UFM 500: user-defined

lowest

highest

Meter size DN in mm

14.2

100

DN

/hr]

[m

Q

2

3

min

100%

×

=

0.05

DN

/hr]

[m

Q

2

3

max

100%

×

=

Meter size (DN) in inches

0.9

DN

/hr]

[m

Q

2

3

min

100%

×

=

3.9

DN

GPM]

[US

Q

2

min

100%

×

=

31.25

DN

/hr]

[m

Q

2

3

max

100%

×

=

138

DN

GPM]

[US

Q

2

max

100%

×

=

Measurement accuracies UFM 400/500

Linearity

for v > 0.5 m/s (> 1.6 ft/s): within ± 0.5%
for v

0.5 m/s (

1.6 ft/s): within ± 2.5 mm/s (0.1 inch/s)

Uncertainty

for size

DN100 (

4”):

within

±

(0.001 x DN [mm]) m

3

/hr

for size < DN100 (<4”):

within

±

(0.0015 x DN [mm]) m

3

/hr

Influence of temperature

Less than

±

0.1% per 10K

Influence of Reynolds number (Re)

single beam flowmeters

double beam flowmeters

± 1% of measured value for Re > 5000
± 0.1% of measured value for a change of Re =100
within the Re 1000 - 4000 range.

Repeatability
single beam flowmeters
double beam flowmeters

better than 0.3% of measured value
better than 0.2% of measured value