beautypg.com

Installation – KROHNE OPTISENS COND 1200 EN User Manual

Page 15

background image

INSTALLATION

3

15

OPTISENS COND 1200

www.krohne.com

01/2014 - 4001967301 - MA OPTISENS COND 1200 R01 en

When ordering the single channel version, only the interface "Pos.A" is populated. In the version
with dual channels the interfaces "Pos.A" and "Pos.B" are populated.

Connecting the sensor cable to the signal converter

• Thread the sensor cable through the middle right cable gland 1.
• Push the wire 7 into the terminal block Pos. A or Pos. B as described in the chart.
• To remove a cable, press down the white clip 8 on the corresponding terminal and pull the

cable out.

1 Sensor connection terminals
2 Terminal block S (protective earth)
3 Terminal block A: terminals for sensor
4 Terminal block B: terminals for sensor

Wire

Terminal block Pos. A / B

Green 2

X

Yellow 3

P

White 4

I

Brown 5

E

.book Page 15 Friday, January 24, 2014 12:32 PM