2.

HARDWARE

2.1

Connectors

There are six connectors on the electronic housing, three of which are directly connected to the transducer assemblies and three
are for the output facilities.

NOTE: To remove the cable connectors from the sensor blocks, fully retract each block into the guide rail by turning the
knurled knob clockwise. DO NOT pull on the cables.

RS 232 CONNECTORS

9 way “D” plug viewed from reverse

5-pin plug viewed from reverse

4 - 20mA and Pulse Cable
Connections
4 - 20mA - Red positive,
Black negative.
Pulse - White positive,
Green negative.

9v DC in
1A Max

RS232

Pulse

4-20 mA

-
+

red

blue

black

Figure 5

Pin 3 RS232 RXD white

Pin 4 RS232 DTR black

Pin 5 GND screen

Pin 2 RS232 TXD green

Pin 6 RS232 DSR red

Pin 5 RS232 RXD white

Pin 4 RS232 TXD green

Pin 1 (marked) RS232 DSR red

Pin 2 RS232 DTR black

Pin 3 GND screen