Technical data – KROHNE WATERFLUX 3070 EN User Manual
Page 64
8
TECHNICAL DATA
64
WATERFLUX 3070
www.krohne.com
06/2013 - 4001410205 - HB WATERFLUX 3070 R05 en
Installation conditions
Installation
Assure that flow sensor is always fully filled.
For detailed information refer to
Installation
on page 15.
Flow direction
Forward and reverse
Arrow on flow sensor indicates forward flow direction.
Inlet run
DN25...300 ≥ 0 DN
DN350...600 ≥ 3 DN
For detailed information refer to
Measurement accuracy
on page 72.
Outlet run
DN25...300 ≥ 0 DN
DN350...600 ≥ 1 DN
For detailed information refer to
Measurement accuracy
on page 72.
Dimensions and weights
For detailed information refer to
Dimensions and weights
on page 74.
Materials
Sensor housing
Sheet steel
Measuring tube
DN25...200: metallic alloy
DN250....600: stainless steel
Flanges
Steel 1.0460 / 1.0038 (RSt37-2)
DN25...DN200; Wetted parts nickel plated
Liner
Rilsan
®
Protective coating
On exterior of the meter: flanges, housing, signal converter (compact
version) and / or connection box (field version)
Standard: polyurethane coating
Option: subsoil coating
Measuring electrodes
Standard: stainless steel 1.4301 / AISI 304
Optional: Hastelloy
®
C
Reference electrode
Standard: stainless steel 1.4301 / AISI 304
Optional: Hastelloy
®
C
Grounding rings
Grounding rings can be omitted when the reference electrode is used.
Signal converter housing
Standard:
Standard:
Standard:
Standard:
Aluminium with a polyester topcoat
Optional:
Optional:
Optional:
Optional:
Polycarbonate (IP68)
Connection box
Only for remote versions.
Stainless steel (IP68)
Process connections
EN 1092-1
Standard:
Standard:
Standard:
Standard:
DN25...200: PN 16
DN250...600 : PN 10
Optional:
Optional:
Optional:
Optional:
DN250...600: PN16 ( DN350...600: 10 bar rated)
ASME
1...12": 150 lb RF (232 psi / 16 bar rated)
14...24": 150 lb (145 psi / 10 bar rated)