4.4 Connection of the output cable

4.4.1 IP67 housing (compact and field version)

Electrical values

• Pulse output passive:

Pulse output passive:

Pulse output passive:

Pulse output passive:
f ≤ 100 Hz; I ≤ 10 mA; U: 2.7...24 VDC (P ≤ 100 mW)

• Status output passive:

Status output passive:

Status output passive:

Status output passive:
I ≤ 10 mA; U: 2.7...24 VDC (P ≤ 100 mW)

Figure 4-5: Removing side cap

Figure 4-6: Terminal assignment

1 Status output 1 or pulse output C
2 Status output 2
3 Not used
4 Common ground
5 Pulse output A
6 Pulse output B