beautypg.com

Operation, 11 battery – KROHNE WATERFLUX 3070 EN User Manual

Page 53

background image

OPERATION

6

53

WATERFLUX 3070

www.krohne.com

06/2013 - 4001410205 - HB WATERFLUX 3070 R05 en

6.3.11 Battery

After a change of battery:

• Reset the bettery lifetime counter (Menu number B2)
• Select the battery type, if a different type of battery is used. (Menu number B0)
• Change the total battery capacity, if a different type of battery is used. (Menu number B1)

No.

Function

Options

Description

A0

Simulate outputs

0 = Off (default)

If set to 1 (=On) the pulse and status

output automatically generate 1

pulse per second. Set back to 0 to

stop the simulation.

1 = On

A1

Reset all counters

88888 = Off (default)

Set to 00000 to reset all counters.

The value of A1 will automatically

switch back to 88888 after the reset.

00000 = Reset

A2

Verification mode

0 = Off (default)

The display indicates Pxxxxxxx, the

decimal separator position varies

per diameter. Please refer to

Verification mode

on page 54, for

more details.

1 = On

A3

Add-on

communication

0 = Off (default)

Factory setting

1 = On

No.

Function

Options

Description

B0

Battery type

0 = No battery

A wrong setting influences the

battery lifetime calculation.

1 = One internal battery

(default)

2 = Two internal batteries

3 = External battery pack

B1

Total battery capacity

xx.xxx = xx.xxx Ah

(19.000 Ah Default)

Total of all batteries in Ah. After a

change to a different battery type,

change the setting (19 one battery,

38 two batteries, or 78 external

battery)

B2

Reset battery lifetime

counter

0 = Off (default)

Set the value to 1 to reset the battery

lifetime counter. After a reset, the

menu setting automatically goes

back to 0.

1 = Reset