beautypg.com

Operation, 6 reset full access to the menu – KROHNE WATERFLUX 3070 EN User Manual

Page 41

background image

OPERATION

6

41

WATERFLUX 3070

www.krohne.com

06/2013 - 4001410205 - HB WATERFLUX 3070 R05 en

6.2.6 Reset full access to the menu

To enable access to the menu again, follow the next steps:

• Remove the protection cap and loosen the 4 Allen bolts (4mm) (IP67 housing).
• Remove the cover.
• Use a small screwdriver to press the reset button.

First press the reset button 1 and then simultaneously press both the optical keys for 6
seconds 2.

• The display will automatically switch to menu number 1.
• To change the setting of menu number 1 from 1 to 0, please refer to

View or change menu

settings

on page 42.

• Tighten the 4 bolts and put back the protection cap (IP67 housing).
• For closing the case of the converter in the IP68 housing, please refer to

IP68 housing,

compact version

on page 26.

WARNING!
Do not break the metrological seals if the meter has been verified to MID Annex MI-001 or OIML
R49 and has received metrological sealing. This can lead to the obligation to re-verify the meter.
Please check your local regulations.

Figure 6-6: Change the settings of the access control.

1

2

WARNING!
Make sure that the battery cable is not jammed by the cover.