Technical data – KROHNE WATERFLUX 3070 EN User Manual

Page 62

background image

8

TECHNICAL DATA

62

WATERFLUX 3070

www.krohne.com

06/2013 - 4001410205 - HB WATERFLUX 3070 R05 en

Measurements

Measuring units

Volume

Volume

Volume

Volume

Default setting: m

3

Selectable: litre, gallon, imperial gallons, cubic feet, acre inch, acre feet

Flow rate

Flow rate

Flow rate

Flow rate

Default setting: m

3

/ hr

Selectable: litre/sec, gallon/min, imperial gallon/min,

cubic feet/hour, acre inch/day, acre feet/day

Measurement interval

Default setting: 15s

Selectable: 1s, 5s, 10s, 15s, 20s

Empty pipe detection

Optional: display shows - EP - in case of empty pipe detection

Low flow cut off

Measurements below this value are neglected

Default setting: 10 mm/s

Selectable: 0 mm/s, 5 mm/s, 10 mm/s

Measuring accuracy

Reference conditions

Medium: water

Temperature: +10...30°C / +50...86°F

Operating pressure: 1 bar / 14,5 psi

Inlet section: 3 DN / Outlet section: 1 DN

Electrical conductivity: > 300 µS/cm

Maximum measuring error

DN25...300; down to 0.2% of the measured value ± 0.5 mm/s

DN350...600; down to 0.4% of the measured value ± 1 mm/s

The maximum measuring error depends on the installation conditions.

For detailed information refer to

Measurement accuracy

on page 72.

Repeatability

DN 25...300; ±0.1% (v >0.5 m/s / 1.5 ft/s)

DN350...600; ±0.2% (v >0.5 m/s / 1.5 ft/s)

Calibration / Verification

Standard:

Standard:

Standard:

Standard:

2 Point calibration by a direct volume comparison.

Optional:

Optional:

Optional:

Optional: for DN25...300

Verification to Measurement Instrument Directive (MID), Annex MI-001.

Standard: Verification at Ratio (Q3/Q1) = 80

Optional: Verification at Ratio (Q3/Q1) > 80

MID MI-001

(Directive 2004/22/EC)

EC-Type examination certificate to MID Annex MI-001

EC-Type examination certificate to MID Annex MI-001

EC-Type examination certificate to MID Annex MI-001

EC-Type examination certificate to MID Annex MI-001

Diameter: DN25...300

Minimum straight inlet flow: 0 DN

Minimum straight outlet flow: 0 DN

Forward and reverse (bi-directional) flow

Orientation: any

Ratio (Q3/Q1): up to 400

Liquid temperature range: +0.1°C / 50°C

Maximum operating pressure: ≤ DN200: 16 bar, ≥ DN250: 10 bar

For detailed information refer to

Legal metrology

on page 67.