INSTALLATION

3

17

WATERFLUX 3070

www.krohne.com

06/2013 - 4001410205 - HB WATERFLUX 3070 R05 en

3.6 Installation conditions

3.6.1 Inlet and outlet

3.6.2 T-section

DN25...300

Figure 3-4: Minimal inlet and outlet

1 Inlet: ≥ 0 DN
2 Outlet: ≥ 0 DN

DN350...600

Figure 3-5: Minimal inlet and outlet

1 Inlet: ≥ 3 DN
2 Outlet: ≥ 1 DN

Figure 3-6: Distance behind a T-section

1 DN 25...300: ≥ 0 DN & DN 350...600: ≥ 3 DN