Press
%
from the power-up screen to enter the General Setup menu (Figure 3-6), then high-
light Max/Min Settings. Press
!
to enter the Max/Min Settings submenu (Figure 3-7). (If a
Password is required, see PAR. 3.2.4.4 for instructions.) Highlight Protect Entry and press
!
to
change it. Highlight Bipolar or Independent, then
$
to save, or
%
to abort. When complete,
press
$
to save for power-up, or
#
to abort, or
%
to apply the changes (without saving for
power-up) and exit.
FIGURE 3-6. GENERAL SETUP MENU
Minimum (box)
+Voltage Protect Min
–Voltage Protect Max
Current mode only. Minimum (positive) setting for +Voltage Protect and
maximum (maximum negative) setting for –Voltage Protect. Values of ±Volt-
age Protect between +Voltage Protect Min and –Voltage Protect Max (near
zero) are not allowed. This zone (also referred to as the minimum (box) is
automatically calculated by the BOP (see Figure 1-3).
N/A
N/A
+Current
–Current
Current mode only. Positive and negative output current established by
keypad or remote command.
Range (+): 0 to +Current max
Range (–): 0 to –Current min
+Current max
–Current min
Current mode only. Maximum (positive) and minimum (maximum
negative) current that can be set.
Value (+): 0 to +I
Onom
Value (–): 0 to –I
Onom
TABLE 3-4. VOLTAGE AND CURRENT PARAMETER DEFINITIONS (CONTINUED)
Term
Definition
To modify
refer to PAR.
Local
Remote