BOP-1K 101509

B-27

B.98 [SOURce:]VOLTage[:LEVel]:PROTect:NEGative COMMAND

VOLT:PROT:NEG

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:PROT:NEG
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:NEGative
where is between minimum (box) value (Figure 1-3) and 1% above rated (nominal) output
voltage.

Description: Establishes the negative protection limit for voltage; maximum is 1% greater than rated output voltage.

B.99 [SOURce:]VOLTage[:LEVel]:PROTect:NEGative? QUERY

VOLT:PROT:NEG?

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:PROT:NEG?
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:NEGative?
Returns:

Description: Identifies the negative protection limit for voltage.

B.100 [SOURce:]VOLTage[:LEVel]:PROTect:POSitive COMMAND

VOLT:PROT:POS

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:PROT:POS
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:POSitive
where is between minimum (box) value (Figure 1-3) and 1% above rated (nominal) output
voltage.

Description: Establishes the positive protection limit for voltage; maximum is 1% greater than rated output voltage.

B.101 [SOURce:]VOLTage[:LEVel]:PROTect:POSitive? QUERY

VOLT:PROT:POS?

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:PROT:POS?
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:POSitive?
Returns:

Description: Identifies the positive protection limit for voltage.

B.102 [SOURce:]VOLTage[:LEVel]:PROTect:LIMit:BOTH COMMAND

VOLT:PROT:LIM[:BOTH]

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:PROT:LIMit[:BOTH]
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:LIM[:BOTH
where is between minimum (box) value (Figure 1-3) and 1% above rated (nominal) output
voltage.

Description: Establishes the maximum value possible for both the positive and negative protection limits for volt-

age. Requires MEM:UPD (PAR. B.12) to save for power up. See PAR. 3.5.2.2 and Figure 3-16 for spe-
cial programming considerations.

B.103 [SOURce:]VOLTage[:LEVel]:PROTect:LIMit[:BOTH]? QUERY

VOLT:PROT:LIM[:BOTH]?

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:PROT:LIM[:BOTH]?
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:LIMit[:BOTH]?
Returns ,

Description: Identifies the maximum value possible for protection limits for voltage (positive, negative); maximum is

1% greater than rated output voltage.

B.104 [SOURce:]VOLTage[:LEVel]:PROTect:LIMit:NEGative COMMAND

VOLT:PROT:LIM:NEG

Syntax:

Short Form: [SOUR:]VOLT[:LEV]:PROT:LIM:NEG
Long Form: [SOURce:]VOLTage[:LEVel]:PROTect:LIMit:NEGative
where is between minimum (box) value (Figure 1-3) and 1% above rated (nominal) output
voltage.
Description:Establishes the minimum (maximum absolute) value possible for the negative protection
limit for voltage. This may be set up to 1% greater than rated voltage. Requires MEM:UPD (PAR.
B.12) to save for power up. See PAR. 3.5.2.2 and Figure 3-16 for special programming consider-
ations.