beautypg.com

4 ciil programming, Ciil programming -9 – KEPCO BIT 4882F User Manual

Page 37

background image

BIT 4882 030507

4-9/4-10

FIGURE 4-3. TYPICAL EXAMPLE OF INTERFACE CARD PROGRAM USING SCPI COMMANDS

4.4

CIIL PROGRAMMING

The CIIL command language is used on early models of Kepco power supplies and controllers.
The command functions are included here for compatibility with other equipment programmed
with CIIL commands. The CIIL command set for the Interface Card is defined and explained in
Appendix C.

/**************************************************************************/

/* Sample Program For KEPCO power supply, using National Instruments */

/* GPIB interface card and IBM PC or compatible computer */

/**************************************************************************/

#include

#include "decl.h"

char rd_str[80];

// Input buffer

char dat_str[80];

// Output buffer

int bd,adr;

main() {

adr = ibfind("DEV6");

// Open DEV6 (defined by IBCONF)

bd = ibfind ("GPIB0");

// Open GPIB card

ibsic (bd);

// Send Interface Clear

ibsre(bd,1);

// Set remote line true

strcpy(dat_str,"VOLT 5;CURR 1");

// Define a set command

strcat(dat_str,"\r\n");

// Append delimiter

ibwrt(adr,dat_str,strlen(dat_str));

// Send string to power supply

strcpy(dat_str,"MEAS:VOLT?;CURR?");

// Define a measure command

strcat(dat_str,"\r\n");

// Append delimiter

ibwrt(adr,dat_str,strlen(dat_str));

// Send string to power supply

strset(rd_str,'\0');

// Clear input buffer

ibrd(adr,rd_str,64);

// Read result of measure

printf("received : %s\n",rd_str);

// Print voltage and current

}

This manual is related to the following products: