beautypg.com

Installation of model bit 4882 into bop -6 – KEPCO BIT 4882F User Manual

Page 18

background image

2-6

BIT 4882 030507

FIGURE 2-3. INSTALLATION OF MODEL BIT 4882 INTO BOP (SHEET 1 OF 2)

NOTE:

Step numbers coincide with encircled numbers on Figure 2-3, sheet 2.

Step 1.

Remove a-c power to BOP by disconnecting line cord.

Step 2.

Remove BOP cover (see Section 5, Figure 5-1 of your BOP Instruction Manual).

Step 3.

Remove and discard Rear Cover Plate (PN 128-1434) and associated hardware.

Step 4.

Remove J204 Connector Assembly (PN 241-0680) from Location #1, save for Step 9.

Step 5.

Locate Transformer T202 and unplug connector from Location #4 only.

Step 6.

Locate Rear Bracket and note part number (stamped on outside left edge):

if not PN 128-1810, contact Kepco.

Step 7.

Unpack the BIT 4882 Interface Card Installation Components (PCB Assembly, Cables #1 and
#2, Connector Assembly, three (3) Knurled Nuts, five (5) washers, Spacer and Bracket).

Step 8.

Install PCB Assembly (PN 235-1166) into the guides, slide into position so that mounting holes
in PCB Assembly line up with the three mounting posts on the BOP mounting bracket.

Step 9.

Secure the BIT 4882 Interface Card to the Mounting Posts using the Knurled Nuts and Lock-
washers. Mount Connector J204 (Ref. Step 4, above) into Location #3 using the Lockwashers,
Hex Spacer and knurled nut.

Step 10. Install Cable #1 (18-position connectors) to the BIT 4882 Interface Card, mate the other end of

the cable with Location #1 on BOP A1 Assembly.

Step 11. Install Cable #2 (5-position connectors) to the BIT 4882 Interface Card, mate the other end of

the cable with Location #2 on BOP A1 Assembly.

Step 12. Plug in 3-pin connector (Ref. Step 5, above) from Transformer 100-2354 as shown.

Step 13. Mark "-4882” after Model No. on Nameplate (see Detail A).

Step 14. Remove "Control Identification" label (PN 188-1107) and "Address Label" (PN 188-1012). Affix

revised "Control Identification" label (PN 188-1445) and "Address Label" (PN 188-1726) in
vacated positions (with part numbers facing front panel).

Step 15. Reinstall BOP cover.

Step 16. Perform calibration procedure detailed in Section 3 of this manual.

This manual is related to the following products: