6 voltage reading zero calibration (r35), Voltage reading zero calibration (r35) -3, Bop power supply, internal calibration controls -3 – KEPCO BIT 4882F User Manual
Page 23
BIT 4882 030507
3-3
2. MEASURE the output voltage at the sense terminals at the BOP front panel using the DVM.
3. Locate VOLTAGE FULL SCALE control R21 (see Figures 2-1 and 3-1, refer to Table 3-1).
4. Adjust control R21 as needed until DVM reads FULL SCALE VOLTAGE, ±1 millivolt.
3.6
VOLTAGE READING ZERO CALIBRATION (R35)
1. Program the BOP power supply for ZERO VOLTAGE and MAXIMUM CURRENT LIMIT.
• If using SCPI send
VOLT 0;CURR MAX
• If using CIIL send
FNC DCS:CH1 VOLT 0 with CURL .5
TABLE 3-1. BOP POWER SUPPLY, INTERNAL CALIBRATION CONTROLS
REFERENCE
DESIGNATION
CONTROL
NAME
PURPOSE
ADJUSTMENT
PROCEDURE
(PAR.)
R19 *
VOLTAGE READING
‘MEASURE’d voltage reading adjustment
3.7
R20 *
CURRENT READING
‘MEASURE’d current reading adjustment
3.11
R21 *
VOLTAGE FULL SCALE
Full scale output voltage adjustment
3.5
R22 *
CURRENT FULL SCALE
Full scale output current adjustment
3.9
A1R31, A1R32
( ± ) 10V CAL.
Reference voltage calibration
3.2
R35 *
VOLTAGE READBACK ZERO
Zero output voltage readback adjustment
3.6
R36 *
CURRENT READBACK ZERO
Zero output current readback adjustment
3.10
R50 *
AMMETER ZERO
Sensing amplifier offset adjustment
3.3
A1R81
EO COMP AMP ZERO
Voltage channel zero adjustment
3.4
A1R83
IO COMP AMP ZERO
Current channel zero adjustment
3.8
* Located on BIT 4882 card