Appendix c - ciil command definitions, Table c-1. ciil subsystem command/query index, Figure c-1. fnc — function command – KEPCO BIT 232F User Manual
Page 53
![background image](/manuals/367864/53/background.png)
BIT 232 022800
C-1
APPENDIX C - CIIL COMMAND DEFINITIONS
C.1
INTRODUCTION
This appendix defines the CIIL commands used with the BIT 232/BIT 232-F Interface Card.
Table C-1 provides a quick reference of all CIIL commands used in the BIT Card.
FIGURE C-1. FNC — FUNCTION COMMAND
TABLE C-1. CIIL SUBSYSTEM COMMAND/QUERY INDEX
COMMAND
PAGE
COMMAND
PAGE
CNF
C-4
RST
C-4
FNC
C-1
SET
C-3
FTH
C-2
SRN
C-3
GAL
C-6
SRX
C-3
INX
C-2
STA
C-5
IST
C-4
Syntax:
Stimulus mode: FNC DCS :CH1
Sensor mode:
FNC DCS
Function:
This operator is used with either the SET command to program a power supply's output (stimulus
mode), or with the VOLT and CURR commands to read its output settings (sensor mode).
Description:
The first operand contains the three (3) letter mnemonic pertaining to the device on the control bus, in
this case DCS (Direct Current Source). If a reading is being set up, the modifier VOLT or CURR fol-
lows. The next operand is used to select the specific channel of the device being programmed or read
from.
Example:
FNC DCS :CH1 SET VOLT 15
Power supply commanded to 15V
FNC DCS :CH1 SET CURR 3
Power supply commanded to 3A
FNC DCS VOLT :CH1
Power supply returns value which represents actual output
voltage
FNC DCS CURR :CH1
Power supply returns value which represents actual output
current
NOTE: Actual output voltage and current depends on load conditions
FNC