Figure b-11. voltage:triggered command, Figure b-12. voltage:triggered query, B-11 vo – KEPCO BIT 232F User Manual
Page 45: B-12 vo, Volt:trig
![background image](/manuals/367864/45/background.png)
BIT 232 022800
B-7
FIGURE B-11. VOLTage:TRIGgered COMMAND
FIGURE B-12. VOLTage:TRIGgered QUERY
Syntax:
Short Form:
VOLT:TRIG
Long Form:
[SOURce]:VOLTage:TRIGgered
Function:
Programs voltage value to be implemented by *TRG command. Actual output voltage will depend on
load conditions.
Description:
This command can be used to reset many power supplies to preselected parameters by issuing a sin-
gle *TRG command.
Example:
VOLT 21; CURR 1.1
Power supply commanded to go to 21V, 1.1A
VOLT:TRIG 29.3
Power supply current programmed to 29.3 upon receipt of *TRG
VOLT?
Controller reads 21, indicating programmed current value = 21V
*TRG
Power supply commanded to voltage value established by VOLT:TRIG
command (29.3) and current value established by CURR:TRIG
VOLT?
Controller reads 29.3, indicating programmed current value = 2.3A
VOLT:TRIG
Syntax:
Short Form:
VOLT:TRIG?
Long Form:
[SOURce]:VOLTage:TRIGgered?
Function:
Returns value to controller representing voltage value to be programmed by *TRG command.
Description:
This command returns the voltage value established by VOLT:TRIG command.
Example:
VOLT 21; CURR 1.1
Power supply commanded to go to 21V, 1.1A
VOLT:TRIG 29.3
Power supply voltage programmed to 29.3 upon receipt of *TRG
VOLT?
Controller reads 21, indicating programmed voltage value = 21V
VOLT:TRIG?
Controller reads 29.3 (voltage value established by VOLT:TRIG
command
VOLT:TRIG?