Software Settings Screen

The Software Settings screen allows you to make changes to communication and
control settings. From the Config menu select Program Software Settings.

Figure 19.1 Software Settings

Screen Text

Description

Use Default Settings

Click this button to restore the system default settings.

Startup Period (Hours)

Idle period prior to sending alerts or controlling so data can
start coming in.

Maximum Interval Between
Communications (Minutes)

This is the amount of time between loss of communication
with the buoy and assumption of zero reading. Then screen
shows red zero and sends alert. (Buoy radios send data
approximately every 4 minutes.)

Maximum Interval Between
Control Communications
(Minutes)

This is the amount of time between loss of communication
with the controller and an assumption of a problem with the
system.

Minimum Time Between
Alerts

Sets how often the system will send a message regarding
an alert.

Early Off Start Time

Allows the aerator to start according to a different DO limit
during the day versus night. Enables aerators to shut off
earlier during the day when oxygen values will likely recover
on their own. The time format is in military time.

Early Off End Time

Time that the Early Off feature stops. The time format is in
military time.