7 aquaculture software, Pond status screen, Aquaculture software – In-Situ Aquaculture Buoy Manual (purchased after 28 May 2013) User Manual
Page 23
23
Aquaculture Software
Pond Status Screen
The Pond Status screen offers a quick view of farm data from the last 24 hours.
Figure 12.1 Annotated Pond Status Quick View screen
1
Calibrate menu (Do not use)
If you need to remove an erroneous adjustment factor, send a value of 25.5.
2
Config menu—Set aerators, send test email, database, program settings
window
3
Status—Farm status window
4
Setup—Farm status window, allows you to configure Farm Status screen
5
Analysis—Access the Communication Test window and the Monitor Analysis
window
6
Language—Select English or Spanish
7
Feeding system menus
8
Pond—User-entered pond name
A small number in the lower-right corner of the box appears when there are 30
or fewer days left on the sensor cap.
9
Dissolved oxygen value—Running average of the last 3 readings. This
average is compared to the on/off limits. Zero is ignored unless there are 3
zeros in a row.
A red zero indicates that the buoy is not communicating with the host . The
buoy power supply, microprocessor, and radio should be checked.
A black zero indicates an oxygen sensor problem. The sensor is not sending
a signal to the microprocessor and needs to be serviced.