HT instruments FULLTEST3 User Manual
Page 85

FULLTEST
3
EN - 84
Global earth resistance without tripping RCD (R
A
)
I
N
(mA)
Display range R
A
(
)
Resolution
(
)
Accuracy
Overvoltage
protection
10
0
2000
1
± (3% rdg. + 1
), 15
2000
*
CAT III 300 V
30
0.0
99.9
0.1
± (3% rdg. + 1
), 10
2000
*
100
2000
1
100
0.0
99.9
0.1
± (3% rdg. + 3 dgt)*
100
1000
1
300
0.0
99.9
0.1
100
300
1
500
0.0
99.9
0.1
100
200
1
650
0.0
99.9
0.1
100
150
1
1000
0.0
100.0
0.1
* The accuracy may be affected unstabile mains voltage!
Test current:
I
N
/2
Input voltage range:
100
265 V, 50/60 Hz
Nominal mains voltage :
230 or 240 V
Mains voltage U
L/PE
:
Display range
(V)
Resolution
(V)
Accuracy
100
265
1 ±
(3%
rdg.)
Input resistance (U
L/PE
): 450
k
Contact voltage U
C
at I
N
:
Display range
(V)
Resolution
(V)
Accuracy
0
100 (U
C LIM
= 50 V)
1
± (3% rdg. + 3 V)
0
50 (U
C LIM
= 25 V)
- COMBI419 (88 pages)
- COMBIG3 (108 pages)
- EQUITEST5071 (44 pages)
- GEO416 (116 pages)
- HT12 (4 pages)
- HT14N (12 pages)
- HT154 (13 pages)
- HT155 (68 pages)
- HT20 (5 pages)
- HT20 (6 pages)
- HT204 (8 pages)
- HT2055 (35 pages)
- HT21 (17 pages)
- HT210 (19 pages)
- HT2234N (14 pages)
- HT300 (9 pages)
- HT307 (11 pages)
- HT309 (13 pages)
- HT32 (23 pages)
- HT321 (16 pages)
- HT326 (21 pages)
- HT327 (21 pages)
- HT3301 (16 pages)
- HT3320 (30 pages)
- HT37 (24 pages)
- HT4000 (15 pages)
- HT401 (24 pages)
- HT4010 (76 pages)
- HT4011 (21 pages)
- HT4012 (84 pages)
- HT4014 (23 pages)
- HT4020 (152 pages)
- HT5 (12 pages)
- HT5000 (31 pages)
- HT6 (16 pages)
- HT603 (5 pages)
- HT70 (6 pages)
- HT701 (26 pages)
- HT7052 (120 pages)
- HT712 (17 pages)
- HT77N (14 pages)
- HT78 (16 pages)
- HT8000 (16 pages)
- HT8051 (74 pages)