GOM-802 DC MILLI-OHM METER

USER MANUAL

⎯ ⎯

6

4. Interface

Handler interface

Signal: START TTL input
Signal: LOW, HIGH, FAIL, PASS, EOT, READY

total 6 TTL outputs.

(This function is valid only under the resistance
measurement mode and the compare mode is
enabled.)

Scanner

Signal: READY, PASS, LOW, HIGH, CLOCK,

STRB total 6 TTL outputs.

(This function is valid only under the resistance
measurement mode and the compare mode is
enabled.)

RS-232 GPIB (option)

IEEE488.1-1987, IEEE488.2-1992 and SCPI-1994

5. ENVIRONMENTAL

Operation
Environment

Indoor use, altitude up to 2000m.
Ambient Temperature 0℃ to 40℃.
Relative Humidity 80% (Maximum).
Installation category II
Pollution Degree 2

Storage temperature

-10℃ to 70℃.

6. GENERAL

Power source

AC 100V/120V/220V/230V±10%, 50/60Hz, 27VA,
22W.

Accessories

Test Lead × 1, Instruction manual × 1,
Programmable manual × 1 (option),
Temperature sensor (option) × 1

Dimension

251(W)×91(H)×291(D) m/m

Weigh

Approx. 3 kg

WARNING To avoid electrical shock, the power cord

protective grounding conductor must be connected to ground.

CAUTIONTo avoid damaging the instrument, do not use it

in a place where ambient temperature exceeds 4

0

.

GOM-802 DC MILLI-OHM METER

USER MANUAL

⎯ ⎯

7

3. PRECAUTIONS BEFORE OPERATION

3-1.Unpacking the Instrument

The product has been fully inspected and tested before shipping from the factory.

Upon receiving the instrument, please unpack and inspect it to check if there is

any damage caused during transportation. If any sign of damage is found, notify

the bearer and/or the dealer immediately.

3-2.Checking the Line Voltage

The product can be applied by any kind of line voltages shown in the table below.

Before connecting the power plug to an AC line outlet, make sure the voltage

selector of the rear panel is set to the correct position corresponding to the line

voltage. It might be damaged the instrument by connecting to the wrong AC line

voltage.

WARNING. To avoid electrical shock the power cord protective

grounding conductor must be connected to ground.

AVERISS: Pour éviter les chocs électriques, le fil de terre du

cordon secteur doit impérativement être relié à la terre.

When line voltages are changed, replace the required fuses shown as below:

Model

Line

voltage

Range

Fuse

Line

voltage

Range

Fuse

GOM-802

100V
120V

90-110V

108-132V

TT0.3A

250V

220V
230V

198-242V
216-250V

T0.25A

250V

WARNING. To avoid personal injury, disconnect the power cord

before removing the fuse holder.