Safety Monitor Relay
INT-03

Typical Wiring Diagram

Multiple Switch Wiring Diagram

GuardSwitches

are shown with the actuators in position—guard is closed. One 300-BT Series GuardSwitch

is required for each safety gate. Up to 50 switches can be used with

INT-03. When using the BLT switch models, the voltage drop (30 ohms) must be taken into consideration.

*300-BLT-

*Or other DPST GuardSwitch

(See the 300-BT Series installation instructions)

( – )

( + )

INT-03-230: 230V AC
INT-03-120: 120V AC
INT-03-024: 24V DC

R e q u i r e d F a s t o r
S l o w - A c t i n g F u s e :
( 2 5 0 V , 5 x 2 0 m m F )
I N T - 0 3 - 2 3 0 : 4 0 m A
I N T - 0 3 - 1 2 0 : 8 0 m A
I N T - 0 3 - 0 2 4 : 1 / 4 A

Required Fast or Slow-
Acting Fuses: 4A (250V,
5x20 mm F

W
H
T

B
L
K

R
E
D

B
L
U

*300-BLT-

W
H
T

B
L
K

R
E
D

B
L
U

Note – The LED on the BLT model will be ON when the guard is open

Fuses: 1 A (250 v)

Multiple DPST GuardSwitches – Shown with actuators in position, all guards closed.

The L.E.D of the BLT model will be on when the guard is open. If multiple guards

are open, L.E.D will be dimmer. The maximum number of GuardSwitches that can

be used is 50, although troubleshooting and line resistance must be considered.

(Do not exceed 30 Ohms of combined contact and line resistance. Each GuardSwitch

will have less than 0.5 Ohms of resistance.)

RESET

A

SAFE

AUX.

B

C

D

Safety Monitor Relay
INT-03

E

F

G

OUTPUTS

230 VAC

60 VDC

120 VAC

30 VDC

LOADS

*300-BLT-

W
H
T

B
L
K

R
E
D

B
L
U

Series Circuit

Parallel Circuit

+

L1

L2

1

2

X1 X2

Y1

Y2

N.O.

N.C.

Note: Only outputs AB and CD are safety outputs. Auxiliary form C output E, F, G may fail in an unsafe condition and should only be used for signaling.