CAUTION

CAUTION

CAUTION

CAUTION

CAUTION

Ensure that power is disconnected before cleaning inside of
unit.

Maintenance and

Maintenance and

Maintenance and

Maintenance and

Maintenance and T

T

T

T

Test

est

est

est

est

Examine the unit semi-annually for accumulation of dirt.

Clean if necessary.

Protocol

Protocol

Protocol

Protocol

Protocol

1.0

Setting Unit Address and Network Baud Rate

1.1

Locate the 8-position dip switch, S1, on the top edge of the RS485 COMM board (Figure 6).

1.2

Unit address range is 00-1F hex. (00-31 decimal). Refer to Table 2.2 for unit address configuration. Set S1

positions 1-5 for the desired unit address configuration.

Table 2.2 Unit Address Switch Configuration

Unit Address

S1-1

S1-2

S1-3

S1-4

S1-5

Hex

Decimal

00

00

OPEN

OPEN

OPEN

OPEN

OPEN

01

01

CLOSED

OPEN

OPEN

OPEN

OPEN

02

02

OPEN

CLOSED

OPEN

OPEN

OPEN

03

03

CLOSED

CLOSED

OPEN

OPEN

OPEN

04

04

OPEN

OPEN

CLOSED

OPEN

OPEN

05

05

CLOSED

OPEN

CLOSED

OPEN

OPEN

06

06

OPEN

CLOSED

CLOSED

OPEN

OPEN

07

07

CLOSED

CLOSED

CLOSED

OPEN

OPEN

08

08

OPEN

OPEN

OPEN

CLOSED

OPEN

09

09

CLOSED

OPEN

OPEN

CLOSED

OPEN

0A

10

OPEN

CLOSED

OPEN

CLOSED

OPEN

0B

11

CLOSED

CLOSED

OPEN

CLOSED

OPEN

0C

12

OPEN

OPEN

CLOSED

CLOSED

OPEN

0D

13

CLOSED

OPEN

CLOSED

CLOSED

OPEN

0E

14

OPEN

CLOSED

CLOSED

CLOSED

OPEN

0F

15

CLOSED

CLOSED

CLOSED

CLOSED

OPEN

10

16

OPEN

OPEN

OPEN

OPEN

CLOSED

11

17

CLOSED

OPEN

OPEN

OPEN

CLOSED

12

18

OPEN

CLOSED

OPEN

OPEN

CLOSED

13

19

CLOSED

CLOSED

OPEN

OPEN

CLOSED

14

20

OPEN

OPEN

CLOSED

OPEN

CLOSED

15

21

CLOSED

OPEN

CLOSED

OPEN

CLOSED

16

22

OPEN

CLOSED

CLOSED

OPEN

CLOSED

17

23

CLOSED

CLOSED

CLOSED

OPEN

CLOSED

18

24

OPEN

OPEN

OPEN

CLOSED

CLOSED

19

25

CLOSED

OPEN

OPEN

CLOSED

CLOSED

1A

26

OPEN

CLOSED

OPEN

CLOSED

CLOSED

1B

27

CLOSED

CLOSED

OPEN

CLOSED

CLOSED

1C

28

OPEN

OPEN

CLOSED

CLOSED

CLOSED

1D

29

CLOSED

OPEN

CLOSED

CLOSED

CLOSED

1E

30

OPEN

CLOSED

CLOSED

CLOSED

CLOSED

1F

31

CLOSED

CLOSED

CLOSED

CLOSED

CLOSED

The Adaptatone should be tested annually or as required

by the authority having jurisdiction to ensure continuous

service.