beautypg.com

Edwards Signaling 5530M-485 User Manual

Millennium signal, Description and operation, Mechanical specifications

background image

CHESHIRE, CT 203-699-3300 FAX 203-699-3365 (CUST. SERV.) 203-699-3078 (TECH SERV.)

Installation Instructions for Catalog Series 5530M-485

Adaptatone

®

Millennium Signal

Description and Operation

Description and Operation

Description and Operation

Description and Operation

Description and Operation

Edwards Adaptatone is a heavy-duty, tone-selectable, stand

alone, indoor/outdoor audible signaling device intended

for industrial applications where high audible output and

microcomputer reliability are required. The Adaptatone

Millennium series are UL and cUL Listed as Audible Signal

Appliances for use in the following hazardous locations.

Catalog

Current (A)

Number

Voltage

Standby

Tone On

Standard Volume

5530M-485Y6

125V DC

0.10

0.21

250V DC

0.02

0.10

120V AC 50/60 Hz

0.10

0.32

240V AC 50/60 Hz

0.10

0.20

5530MHV-485Y6

125V DC

0.10

0.39

250V DC

0.02

0.19

120V AC 50/60 Hz

0.10

0.56

240V AC 50/60 Hz

0.10

0.34

5530MV-485Y6

125V DC

0.10

0.20

250V DC

0.02

0.10

120V AC 50/60 Hz

0.10

0.31

240V AC 50/60 Hz

0.10

0.20

Figure 1. Dimensions

P/N 3100345 ISSUE 2 © 2002

Catalog

Hazardous

Temp.

Number

Locations

Code

5530M-485Y6

Class I, Div. 2, Groups A, B, C, D

T4 (135C)

5530MHV-485Y6

Class II, Div. 2, Groups F, G

T5 (100C)

5530MV-485Y6

Class III, Div. 1 and 2

The Adaptatone operates from local power and sounds a

high decibel signal determined by the setting of minia-

ture programming switches inside the unit. The

Adaptatone may be programmed for any of the 27 tones

listed in Figure 7.
Speaker direction and the output level are easily adjust-

able.

Mechanical Specifications

Mechanical Specifications

Mechanical Specifications

Mechanical Specifications

Mechanical Specifications

Weight ................................................... 9 Pounds (4.1 kg)
Hazardous Locations, UL Standard UL1604

Ambient Temp. ................... +41F to +104F (+5C to +40C)
Non-Hazardous Locations

Variable Ambient Temp. ..... -40F to +151F (-40C to +66C)

1. Mount Adaptatone as shown in Figure 2.

a. Flat Surface Mounting. Secure unit to

mounting surface using the (4) mounting holes in

the mounting plate on the rear of the box. Use

the #10 x 3" (76 mm) wood screws (furnished loose)

or other hardware (not supplied) suitable for the

mounting surface.

b. Rigid Pipe Mounting. Loosen the (4) cover screws

from the signal box and lift off signal box cover.

CAUTION

CAUTION

CAUTION

CAUTION

CAUTION

During installation, care must be taken so that components
on the printed circuit board are not damaged.

Electrical Specifications

Electrical Specifications

Electrical Specifications

Electrical Specifications

Electrical Specifications

Installation

Installation

Installation

Installation

Installation

The Adaptatone may be mounted to any flat surface or

may be used as a freestanding unit mounted to a rigid

pipe. The Adaptatone must be installed in accordance

with the latest edition of the National Electrical Code or

other regulations applicable to the country and locality

of installation and by a trained and qualified electrician.

Dimensions

5530M

5530MHV

A

8 7/8"

11 1/2"

(225 mm)

(292 mm)

B

8 1/4"

9 3/4"

(210 mm)

(248 mm)

C

13"

14 1/4"

(330 mm)

(362 mm)