Specifications – Edwards Signaling 5532M User Manual
Page 8
8 / 10
P/N 3100010 • REV 7 • ISS 04AUG10
Specifications
Voltage
Refer to Table 2 and Table 3
Current
Refer to Table 2 and Table 3
Dimensions
Refer to Table 4 on page 9
Weight
Tone Generator
Speaker/Amp
6 lb (2.7 kg)
9 lb (4.1 kg)
Hazardous locations
Ambient
temp.
-31 to 104°F (-35 to +40°C)
Non-hazardous
locations
Variable
ambient
temp
-40 to 151°F (-40 to +66°C)
Table 1: Operating temperature codes
Catalog number
Class I, Div. 2
Groups A, B, C, D
Class II, Div. 2,
Groups F, G
Class III, Div. 1 and
2
5532M-AQ
5532M-N5
5532MHV-AQ
5540M-24AQ
5540M-24N5
5540MV-24N5
5540M-120N5*
135°C (T4)
100°C (T5)
5532M-Y6
5532MHV-Y6
5540M-24Y6
5540MV-24Y6
5540M-120Y6*
180°C (T3A)
100°C (T5)
Table 2: Input board
Catalog number
Voltage
Current
5540M-24AQ
5540M-24N5
5540MV-24N5
5540M-24Y6
5540MV-24Y6
24 VDC
6 mA
5540M-120N5
5540M-120Y6
120V 50/60 Hz
13 mA
Table 3: Main power
Catalog number
Voltage
Standby
current
Tone on
current
Tone Generator
5540M-24AQ 24
VDC
24 VAC 50/60 Hz
0.10 A
0.10 A
0.74 A
1.3 A
5540M-24N5
5540MV-24N5
120 VAC 50/60 Hz
0.10 A
0.36 A
5540M-24Y6
5540MV-24Y6
125 VDC
250 VDC
120 VAC 50/60 Hz
240 VAC 50/60 Hz
0.10 A
0.02 A
0.10 A
0.10 A
0.21 A
0.10 A
0.32 A
0.20 A
Catalog number
Voltage
Standby
current
Tone on
current
5540M-120N5
120 VAC 50/60 Hz
0.10
0.38 A
5540M-120Y6
125 VDC
250 VDC
120 VAC 50/60 Hz
240 VAC 50/60 Hz
0.10 A
0.02 A
0.10 A
0.10 A
0.20 A
0.10 A
0.31 A
0.20 A
Speaker/Amplifier – Standard Volume
5532M-AQ
24 VDC
24 VAC 50/60 Hz
0.10 A
0.10 A
0.74 A
1.3 A
5532M-N5
120 VAC 50/60 Hz
0.10 A
0.36 A
5532M-Y6* 125
VDC
250 VDC
120 VAC 50/60 Hz
240 VAC 50/60 Hz
0.10 A
0.02 A
0.10 A
0.10 A
0.21 A
0.10 A
0.32 A
0.20 A
5532B-AQ
24 VDC
36 VDC
24 VAC 60 Hz
24 VAC 50 Hz
0.06 A
0.07 A
0.26 A
0.26 A
0.69 A
0.84 A
1.36 A
1.36 A
5532B-N5
120 VAC 60 Hz
120 VAC 50 Hz
0.10 A
0.09 A
0.29 A
0.29 A
5532B-Y6
125 VDC
250 VDC
120 VAC 60 Hz
240 VAC 60 Hz
120 VAC 50 Hz
240 VAC 50 Hz
0.05 A
0.04 A
0.10 A
0.11 A
0.09 A
0.10 A
0.16 A
0.10 A
0.29 A
0.23 A
0.29 A
0.22 A
Speaker/Amplifier – High Volume
5532MHV-AQ
24 VDC
24 VAC 50/60 Hz
0.10 A
0.10 A
1.5 A
2.3 A
5532MHV-Y6
125 VDC
250 VDC
120 VAC 50/60 Hz
240 VAC 50/60 Hz
0.10 A
0.02 A
0.10 A
0.10 A
0.39 A
0.19 A
0.56 A
0.34 A
5532BHV-AQ
24 VDC
36 VDC
24 VAC 60 Hz
24 VAC 50 Hz
0.06 A
0.07 A
0.26 A
0.26 A
1.51 A
1.98 A
1.86 A
1.86 A
5532BHV-Y6
125 VDC
250 VDC
120 VAC 60 Hz
240 VAC 60 Hz
120 VAC 50 Hz
240 VAC 50 Hz
0.05 A
0.04 A
0.10 A
0.11 A
0.09 A
0.10 A
0.25 A
0.23 A
0.62 A
0.33 A
0.62 A
0.33 A
*5532M-Y6 is suitable for use with 120 / 240 VAC main power input
in conjunction with the 5541M-Y6 Millennium System Master either
for emergency / evacuation, non-fire, or for supplementary fire
alarm control panel accessory applications (see instructions for
5541M-Y6, part 3100471).