Settings / parameter descriptions 21
Arrow keys:
The arrow keys can be used to display all the temperature values in a
block one after the other.
EMI:
Shows the emissivity that was set when the measured value was stored.
MODE:
If maximum value storage or average value display were active while the
measured values were being stored, only maximum or average values will
be saved. In that case "MAX" or "AVG" appears in the display.
Block:
Shows the current block and the total number of blocks.
No.:
Shows the measured values in the current block. A measured value is
assigned to each number in the block. The arrow keys can be used to
display values one after the other.
Date / time:
Shows the data and time of the stored values.
MEM CELL (Nr.):
Shows the storage slot position of the current measured value.
To switch quickly from one block to the next, first switch to graphic display with the
NUM/GRAPH push button and then select another block with the arrow keys. Pressing the
NUM/GRAPH push button again switches back to numeric view and the content of the block
that is now selected can be viewed.
GRAPH: In graphic mode, the content of each block is shown graphically. If a block contains
only one value, only one line is displayed. If there are several different values, a graph appears
according to the number of stored values. The relevant maximum and minimum values define
the scaling of the Y-axis. Scaling in the direction of the X-axis depends on the number of
measured value to be displayed. The display is 128 pixels wide. If there are exactly those
numbers of measured values, one value is assigned to each pixel. If there are more or fewer
values in the block, the graph will be compressed or stretched to fit the 128 pixels. Manual
scaling is not possible.
Overview:
Arrow keys:
The arrow keys can be used to display all the temperature values in a
block one after the other.
EMI:
Shows the emissivity that was set when the measured value was stored.
Measured value:
Top right the last measured value of the measurement series is shown.
Values to the left: Shows the maximum, average and minimum values from the block.
TOT:
If there is only one value in the block (single value storage), the storage
date and time are shown. If there are several values in the block
(continuous storage), the total time required is displayed.
BLOCK:
Shows the data and time of the stored values.
PAR EMI 95,0%
TOT 00:00:07:700 BLOCK
Set emission level
Displayed block + number
of saved blocks
Last measured value
Maximum value of the block
Average value of the block
Minimum value of the block
Total time of the block or date
/ time of the individual value
Graphic display of saved
measurement curve
MEM CELL
°C
MODE
Block
Set emissivity
Saved measured value
PAR
Current block + numb. of
blocks
Parameter mode
Date when measured values
were recorded
Add. measurement mode if
any
Measured value no. +
number of values in the
Time when measured values
were recorded
Storage cell parameters
Storage slot of the measured
value
NUM