FEED MANAGEMENT SYSTEM

Page 13 of 15

**DIAGNOSTICS**

"

For Qualified Technician Use Only:

(1)Power Ventilation Auxilary SWX:

(2)Ignore Inlet #1 Auxiliary SWX = Yes

(3)Ignore Inlet #2 Auxiliary Swx = Yes

(4)Natural Ventilation Auxiliary SWX:

(5)Ignore Unit #1 Auxiliary SWX = Yes

(6)Ignore Unit #2 Auxiliary Swx = Yes

(7)Feed Level Sensor:

(8)Maximum Range = 26.00 ft

(9)Dead Zone = 1.50 ft

(10)GPAD12 = 115

GPAD13 = 105

GPAD14 = 98

GPAD15 = 90

(11)Soft Resets = 0

(12)Voltage Resets = 0

(13)Hard Resets = 0

One other setting has to be verified by going to the Diagnostic screen.




















Under Feed Level Sensor you will find the term Dead Zone. This refers to the area that the sensor is hanging into
the feed bin. Figure 11 shows how to measure the Dead Zone.





















The measurement should be taken from the top of the cap (excluding the lid ring) to the bottom of the sensor probe.
This measurement is the Dead Zone that should be entered.

Dead Zone