Console port pin assignments – Brocade NetIron CER 2000 Series Hardware Guide (Supporting R05.6.00) User Manual
Page 74
64
Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide
53-1003029-02
Port specifications
5
ports as described in GR-1089-CORE, Issue 4) and require isolation from the exposed OSP
cabling. The addition of Primary Protectors is not sufficient protection in order to connect these
interfaces metallically to OSP wiring.
Console port pin assignments
The console port is a standard male DB-9 connector, as shown in
.
FIGURE 45
Console port pin and signalling details
Most PC serial ports require a cable with a female DB-9 connector. However, terminal connections
will vary, requiring a cable with either a DB-9 or DB-25 connector, male or female.
Serial cable options between the Brocade device and a PC or terminal are shown in
NOTE
As indicated in
, some of the wires should not be connected. If you do
connect the wires that are labeled “Reserved”, you might get unexpected results with some
terminals.
Pin number
Switch signal
1
Reserved
2
TXD (output)
3
RXD (input)
4
Reserved
5
GND
6
Reserved
7
Reserved
8
Reserved
9
Reserved