Printing the displayed data – Yokogawa PC-Based MX100 User Manual
Page 53

5
IM MX100-0E
Printing the Displayed Data
To print waveforms, open the waveform display window; to print numeric values, open
the numeric display window. If multiple windows are open, click the window that you wish
to print. To print values read by the cursors or statistical computation over an area, open
those windows also.
After selecting the object to be printed, choose
Print Setting from the File menu. In the
Print Setting dialog box, set
Range, Color, and Print Groups, and then click OK. Then,
choose
Print from the File menu to execute the printing. When printing numeric values,
you only need to set the range.
Enter the comment to be printed
Switch to settings for numeric values
Select the groups when Selected
Groups is selected
Click to open the group selection dialog box
Select monochrome or color print
Select the group to be printed
Select to print all or print only the range specified by cursors
Converting the Format of the Recorded Measured Data
Conversion can be made into the following formats.
ASCII
Text data with each data point separated by a comma. The extension is .txt.
Excel
Data that can be opened using Microsoft’s spreadsheet application Excel version 8.0
(Excel 97) or later. The extension is .xls.
Lotus
Data that can be opened using IBM’s Lotus 1-2-3 spreadsheet application version 2.0
or later. The extension is .wj2.
From the
Convert menu, choose To ASCII, To Excel, or To Lotus. Then, convert the
data using the dialog box that opens (see the figure below). There is a limitation in the
number of data points that can be handled in the Excel conversion or Lotus conversion.
Before executing the conversion, set the channels/groups to be converted, the
conversion range, and the step so that the number of data points is appropriate.
Enter the range of group numbers to be converted
Select whether to set the range to
be converted using groups or
channels
Select the range of channels to be
converted
Click to open the selection dialog box.
Select the measurement interval
Only the channels with the selected
measurement interval are converted
Enter the data range to be converted
Can be specified using cursors before
opening this dialog box
Displays the time of the specified data
When changing the save destination or file name
Click to open the save destination and file name setup dialog box.
Step when saving data at certain
intervals
Displays the save destination and
file name
Operations of the MX100 Standard Software