Setting alarms – Yokogawa PC-Based MX100 User Manual
Page 42

4
IM MX100-0E
Setting Alarms
Click
Channel on the Monitor bar to display the Channel setup screen. Enter settings in
the
Meas. Channel or Math Channel tab.
Scroll to the right to
display alarms 1 to 4
Hysteresis of alarm 3
Alarm value of alarm 3
Alarm 3 type
Hysteresis of alarm 2
Alarm value of alarm 2
Alarm 2 type
Hysteresis of alarm 1
Alarm value of alarm 1
Alarm 1 type
For measurement
channels
Click
Displaying Alarms on the Trend Waveform Display
The interval while an alarm is occurring is indicated by a bar at the bottom section of the
waveform display area (see the figure below).
Alarm display area
Show/Hide alarm
Switch the active
channel
Period of alarm occurrence
Alarm Indication on the Numerical Display
Four alarm signals are displayed above the measured value (see the figure below). The
changes in the color of these alarm signals indicate the alarm status.
Alarm 1 status
Alarm 2 status
Alarm 3 status
Alarm 4 status
Black: Alarm not set
Green: Alarm OFF
Red: Alarm occurrence
Operations of the MX100 Standard Software