Recording and saving, Recording and saving -3, Index recording and saving – Yokogawa Removable Chassis DX1000N User Manual
Page 8
1-3
IM 04L41B01-03E
Description of the Multi Batch Function
1
2
3
Index
Recording and Saving
Starting and Stopping Recording (Memory Sampling)
You can start and stop recording for each batch group individually. Or, you can start and
stop recording across all batch groups simultaneously.
Feature
Operation Example
Report
Relay output
Instrument
information
output
Computation Starting
computation
using the
START key
(Math start
of the Math
start action)
▼
▼
▼
▼
▼
▼
▼
Batch Group 1
Batch Group 2
Batch Group 3
Simultaneous start
Simultaneous stop
Start
Start
Stop
Start
Stop
Start
Stop
▼
Stop
Start
Stop
Off
Start
Reset + Start
Relay output when recording
stops
Reset and start computation
Do not start computation
Start computation
Recording
Start and stop batch groups individually
Simultaneous start and stop
• Starting and Stopping a Report (/M1 and /PM1 Option)
The report feature starts when you start recording on any batch group and it stops
when all batch groups stop recording.
• Starting and Stopping Computation (/M1 and /PM1 Option)
• All computations start and stop together at the same time.
• When computations are stopped, you can start recording and computation at the
same time.
Math Start Action
Action
Start
Starts computation.
Reset+Start
When starting
each batch group
separately
Resets the values calculated on the
selected batch group’s computation
channels
*
.
Only the flags being used on the
computation channels are cleared to zero.
The DX then starts computation again.
When starting
all batch groups
simultaneously
Resets the values calculated on all
computation channels for the batch groups
that are not recording
*
.
Only the flags being used on the
computation channels are cleared to zero.
The DX then starts computation again.
* The computation channels registered to that batch group’s display group.
• You can stop computation at any time.
1.1 Recording and Saving Data