Using the func key – Yokogawa Removable Chassis DX1000N User Manual
Page 33
3-12
IM 04L41B01-03E
• Using the FUNC Key
You can use the FUNC key for the following operations. For operating procedures,
see the reference for each respective operation. Entries marked with a † function the
same as in batch overview mode.
Operation Name Description
Reference
† Alarm ACK
Executes alarm acknowledgement
for all activated alarms.
Section 3.8 in the User’s Manual.
† Alarm display
reset
Resets the alarm display.
Section 3.12 in the User’s
Manual.
Message
Writes messages for the selected
batch group.
Section 3.6 in this manual.
Free message
Writes messages for the selected
batch group.
Section 3.6 in this manual.
† Media eject
Puts the external memory into
a state in which it can be safely
removed from the DX.
Operation Guide.
† Snapshot
Saves the screen image data from
the active display to a CF card (in
PNG format).
Section 6.6 in the User’s Manual.
† Manual sample
Saves the instantaneous values of
all channels.
Section 6.5 in the User’s Manual.
Save display data Saves display data for the selected
batch group.
Section 3.1 in this manual.
Save event data
Saves event data for the selected
batch group.
Section 3.1 in this manual.
† Save stop
Aborts the manual data saving
operation in progress.
Section 4.8 in the User’s Manual.
Computation
reset
Resets the computed results of
all computation channels for the
selected batch group.
Section 3.2 in this manual.
† Math ACK
Clears the computation data
dropout display.
Section 9.4 in the User’s Manual.
† Edge switch
Sets the event edge switch to on.
Section 7.1 in the User’s Manual.
† Timer reset
Resets the relative timer.
Section 7.1 in the User’s Manual.
† Match timer reset Resets the single match time timer. Section 7.1 in the User’s Manual.
† Locked ACK
Executes the Locked ACK
operation.
IM04L41B01-05EN.
† Key lock
Locks or unlocks keys.
Section 8.1 in the User’s Manual.
† Logout
Logs off from the DX.
Section 8.3 in the User’s Manual.
† Password change Changes the password used to log
on to the DX.
Section 8.3 in the User’s Manual.
Batch
Sets the batch name and comment
for the selected batch group.
Section 6.3 in the User’s Manual.
Text field
Displays the text field for the batch
group that you select.
Section 3.8 in this manual.
Builder screen
Switches to builder screen mode.
IM04L41B01-04E.
† Favorite
registration
Registers the current display as a
favorite.
Section 3.7 in this manual.
4-Panel
*
Registers the 4-panel configuration
and changes the 4-panel display
names.
Section 4.10 in the DX2000
User’s Manual.
† Standard display
Registers the current display as
the standard DX display.
Section 5.14 (DX1000)
Section 5.15 (DX2000)
in the User’s Manual
† SNTP
Synchronizes the DX’s time with
an SNTP server.
Section 1.8 in the Communication
Manual.
† E-Mail start/stop
Starts or stops e-mail transmission. Section 1.4 in the Communication
Manual.
† E-Mail test
Confirms sending of e-mail and the
details of the transmission.
Section 1.4 in the Communication
Manual.
† FTP test
Checks the connection between
the DX and the FTP server.
Section 1.7 in the Communication
Manual.
* Only for the DX2000.
3.5 Using Batch Single Mode