2. operating specifications, 2. operating specifications -2 – Yokogawa DO402 Dissolved Oxygen Analyzer User Manual
Page 18

IM 12J05D02-01E
2-2 Specification
J. Contact outputs
- General : Four (4) SPDT relay contacts
with LED indicators. For S1,
S2, and S3, the LED is on
when relay is powered.
NOTE:
For S4 (FAIL) LED lights when
power is removed (Fail safe).
Contact outputs configurable
for hysteresis and delay time.
- Capacity
: Maximum values 100 VA,
250 V AC, 5 Amps.
Maximum values 50 Watts,
250 V DC, 5 Amps.
- Status
: High/Low process alarms,
selected from process
parameters and temperature.
Contact output is also available
to signal “Hold Active
Contact S1 to S3
Contact S4
Status
LED
NO
NC
LED
ON
NC
Alarm,
FAIL,
OFF
On
Closed
Open
On
Open
Closed
Alarm,
FAIL,
OFF
Off
Open
Closed
Off
Closed
Open
Power
OFF
Off
Open
Closed
Off
Open
Closed
- Control function
: On/Off
PI pulsed Proportional duty cycle control
with integral term.
PI frequency Proportional frequency control
with integral term. In addition
wash cleaning control signal on
S3, and FAIL alarm for system
and diagnostic errors on S4
K. Contact input: Wash start or input remote range
change (either choice)
On resistance: 10Ω or less
Off resistance: 100kΩ or more
On time:
0.5 sec. or more
L. Power supply
Supply voltage rating
: 100, 115, 230 VAC
Applicable range
: 85 to 115, 97.8 to 132.2,
195.5 to 264.5 VAC
Supply frequency rating
: 50 / 60 Hz
Applicable range
: 50 Hz ± 5% / 60 Hz ± 5%
Power consumption
: Maximum 10 VA for steady
operation
M. Safety and EMC conforming standards
,
Safety:
conforms to EN 61010-1
EMC:
EN 61326-1 Class A, Table 2 (For
use in industrial locations) (Note 1)
EN 61326-2-3
EN 61000-3-2 Class A
EN 61000-3-3
EMC Regulatory Arrangement in
Australia and New Zealand
EN 55011 Class A, Group 1
Korea Electromagnetic Conformity
Standard Class A
한국 전자파적합성 기준
Installation altitude: 2000 m or less
Category based on IEC 61010: II (Note 2)
Pollution degree based on IEC 61010:2 (Note 2)
Note 1: This instrument is a Class A product,
and it is designed for use in the
industrial environment. Please use
this instrument in the industrial
environment only.
A급 기기 (업무용 방송통신기자재)
이 기기는 업무용(A급) 전자파적합기기로서 판매자 또는
사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서
사용하는 것을 목적으로 합니다.
Note 2: Installation category, called over-
voltage category, specifies impulse
withstand voltage. Category II is for
electrical equipment.
Pollution degree indicates the degree
of existence of solid, liquid, gas or
other inclusions which may reduce
dielectric strength. Degree 2 is the
normal indoor environment.
N. Shipping details
: Package size w x h x d
290 x 300 x 290 mm.
11.5 x 11.8 x 11.5 in.
Packed weight approx.
2.5 kg (5lb).
2-2. Operating specifications
A. Performance : DO (at t process = 25 °C)
- Linearity : ± 0.03 mg/l or ± 0.5%FS,
whichever is greater
- Repeatability: ± 0.03 mg/l or ± 0.5%FS,
whichever is greater
- Accuracy : ± 0.05 mg/l or ± 0.5%FS,
whichever is greater