beautypg.com

3 optional specifications, Optional specifications -5 – Yokogawa EJX115A User Manual

Page 51

background image

<9. General Specifications>

9-5

IM 01C25K01-01E

9.3 Optional Specifications

Item

Description

Code

Factory Mutual (FM)

FM Explosionproof *

1

Explosionproof for Class I, Division 1, Groups B, C and D

Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G

Hazardous (classified) locations, indoors and outdoors (NEMA 4X)

FF1

FM Intrinsically safe *

1

*

2

Intrinsically Safe for Class I, Division 1, Groups A, B, C and D, Class II,

Division 1,Groups E, F and G and Class III, Division 1 Hazardous Locations.

Nonincendive for Class I, Division 2, Groups A, B, C and D, Class II,

Division 2, Groups F and G Hazardous Locations.

FS1

Combined FF1 and FS1 *

1

*

2

FU1

ATEX

ATEX Flameproof *

1

II 2G, 2D Ex d IIC T6...T4 Gb, Ex tb IIIC T85°C Db

Special fastener: ClassA2-50(A4-50) or more

KF22

ATEX Intrinsically safe Ex ia *

1

*

2

II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85°C T100°C T120°C Db

KS21

Combined KF22, KS21 and ATEX Intrinsically safe Ex ic

*1*3

Ex ic: II 3G Ex ic IIC T4 Gc

KU22

Canadian Standards

Association (CSA)

CSA Explosionproof *

1

Explosionproof for Class I, Groups B, C and D

Dustignitionproof for Class II/III, Groups E, F and G

Enclosure TYPE 4X, Temp.Code:T6...T4

Ex d IIC T6...T4 Enclosure IP66 and IP67

Process Sealing Certification

Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01

No additional sealing required

Primary seal failure annuniciation: at the zero adjustment screw

CF1

CSA Intrinsically safe *

1

*

2

[For CSA C22.2]

Intrinsically safe for Class I, Division 1, Groups A, B, C and D, Class II,

Division 1, Groups E, F and G, Class III, Division 1

Nonincendive for Class I, Division 2, Groups A, B, C and D, Class II,

Division 2, Groups E, F and G, Class III, Division 1

[For CSA E60079]

Ex ia IIC T4, Ex nL IIC T4

Process Sealing Certification

Dual Seal Certified by CSA to the requirement of ANSI/ISA 12.27.01

No additional sealing required

Primary seal failure annuniciation: at the zero adjustment screw

CS1

Combined CF1 and CS1 *

1

*

2

CU1

IECEx

IECEx flameproof *

1

Flameproof for Zone1, Ex d IIC T6...T4

SF2

IECEx Intrinsically safe, type n and flameproof *

1

*

2

Intrinsically safe and type n

Ex ia IIC T4, Ex nL IIC T4

Flameproof

Flameproof for Zone1, Ex d IIC T6...T4

SU2

Combination of Approval

Combination of KU22, FU1 and CU1

V1U1

Painting

Color change

Amplifier cover only *

9

P

Amplifier cover and terminal cover, Munsell 7.5 R4/14

PR

Coating change Anti-corrosion coating *

3

*

9

X2

316 SST exterior parts

316 SST name plate, tag plate and zero-adjustment screw *

10

HC

Fluoro-rubber O-ring

All O-rings of amplifier housing. Lower limit of ambient temperature: –15°C (5°F)

HE