<4. Installation>

4-2

IM 01C25K01-01E

F0402.ai

Vertical pipe mounting

(Process connector upside)

Vertical pipe mounting

(Process connector downside)

Transmitter

mounting bolt

Transmitter

mounting bolt

Mounting bracket

Mounting bracket

U-bolt nut

U-bolt nut

U-bolt

U-bolt

50 mm(2-inch) pipe

50 mm(2-inch) pipe

Figure 4.2

Transmitter Mounting

(Vertical Impulse Piping Type)

4.3 Changing the manifold

assembly

The transmitter is shipped with the manifold

assembly specified at the time of ordering. To

change the manifold assembly, the drain (vent) plug

must be repositioned.
To reposition a drain (vent) plug, use a wrench to

slowly and gently unscrew it. Then, remove and

remount it on the opposite side. Wrap sealing tape

around the drain (vent) plug threads (*1 in the figure

below), and apply a lubricant to the threads of the

drain (vent) screw(s) (*2 below). To tighten the drain

(vent) plugs, apply a torque of 34 to 39 N·m {3.5 to 4

kgf·m}. Manifold bolts are to be tightened uniformly

to a torque of 39 to 49 N·m {4 to 5 kgf·m}.

F0403.ai

*1
*2

Drain/vent plug

Note: For a horizontal impulse

piping type, moving the

Manifold Assembly from

the front side to the

back cannot be made.

Vertical impulse piping type

Horizontal impulse piping type

Bolt

Process connector

gasket

Manifold

Figure 4.3

Changing Manifold Assembly

4.4 Swapping the High/Low-

pressure Side Connection

This procedure can be applied only to a transmitter

with a vertical impulse piping type.
The procedure below can be used to turn the

pressure detector assembly 180°. Perform

this operation in a maintenance shop with the

necessary tools laid out and ready for use, and then

install the transmitter in the field after making the

change.
1) Use an Allen wrench (JIS B4648, nominal 2.5

mm) to remove the two setscrews at the joint

between the pressure-detector section and

transmitter section.

2) Leaving the transmitter section in position,

rotate the pressure-detector section 180°.