beautypg.com

Yokogawa EJA440E User Manual

Page 76

background image

<4. Diagnostics>

4-29

IM 01C25T01-06EN

Integral

Indicator

HART configuration

tool display

Device Status

Extended

Device Status

Value and Status (Data Quality and Limit Status)

Differential

Pressure

(DP)

Static

Pressure

(SP)

Temperature

(T)

% range

Loop current

AL.35

P. HI

P high alarm *

1

Pressure High

Alarm *

2

---

Device

Variable Alert

(0x02)

Value: Measured value

Status: Good and Not Limited

AL.36

P. LO

P low alarm *

1

Pressure Low

Alarm *

2

AL.37

SP. HI

SP high alarm *

1

Static Pressure

High Alarm *

2

AL.38

SP. LO

SP low alarm *

1

Static Pressure

Low Alarm *

2

AL.50

P. LRV

Illegal P LRV *

1

Illegal Pressure

LRV *

2

Value: Measured value

Status: Good and Not Limited

Value: Hold value

Status: Bad and Constant

AL.51

P. URV

Illegal P URV *

1

Illegal Pressure

URV *

2

AL.52

P. SPN

Illegal P SPAN *

1

Illegal Pressure

SPAN *

2

AL.53

P. ADJ

P SPAN trim err *

1

Pressure SPAN

Trim Error *

2

Value:

Measured

value

Status:

Poor

Accuracy and

Not Limited

Value:

Measured value

Status:

Good and Not Limited

Value: Measured value

Status: Poor Accuracy and

Not Limited

P ZERO trim

err *

1

Pressure ZERO

Trim Error *

2

AL.54

SP. RNG

Illegal SP LRV *

1

Illegal Static

Pressure LRV *

2

Value: Measured value

Status: Good and Not Limited

Value: Measured value

Status: Good and Not

Limited

Illegal SP URV *

1

Illegal Static

Pressure URV *

2

Illegal SP SPAN

*

1

Illegal Static

Pressure SPAN *

2

AL.55

SP. ADJ

SP SPAN trim

err *

1

Static Pressure

SPAN Trim Error

*

2

Value:

Measured

value

Status:

Good and Not

Limited

Value:

Measured

value

Status:

Poor

Accuracy and

Not Limited

Value:

Measured

value

Status:

Good and Not

Limited

Value: Measured value

Status: Good and Not

Limited

SP ZERO trim

err *

1

Static Pressure

ZERO Trim Error

*

2

AL.60

SC.CFG

SC config error

Value: Measured value

Status: Good and Not Limited

AL.79

OV.DISP

---

---

---

Value: Measured value

Status: Good and Not Limited

*1: DD and DTM (excluding EJX HART 5 DTM based on FDT1.2)

*2: EJX HART 5 DTM based on FDT1.2

*3: Depend on the setting of hardware switch

*4: Depend on the direction of range over (high or low)

This manual is related to the following products: