SpecView from Watlow

 17 

Watlow Addendum

8) For the Port to

which the
controllers are
attached, choose the
appropriate protocol
driver in Protocol.
See the table below.

Note: If there are controllers

on the same port that
require different drivers,
you will need to repeat
steps 8 to 10 for each
protocol.

9) Click Start Scan.

For this Controller…

Choose this Protocol
Driver…

Notes

EZ-ZONE PM, RM or ST

Watlow EZ-ZONE
Standard Bus

SERIES 96, 97, SD
MICRODIN,
POWER SERIES,
986, 987, 988, 989

Watlow Modbus

SERIES F4 Ramping

Watlow Modbus
Watlow F4 Programmer

1

For the SERIES F4 Profiling controller, scan twice,
once with each protocol driver. Add the F4 Cascade
instrument manually if desired. See Manually Set up
or Modify a Modbus RTU, 485 or 232 Network
on
page 22.

16CLS, 16MLS,
CLS216, MLS316

Anafaze 16 Loop

CLS200 and MLS300 Standard and Ramp/Soak
firmware options. For controllers with Ramp/Soak to
add the Anafaze Profile Status and the desired
Anafaze Profile instruments. See Manually Set up or
Modify a Modbus RTU, 485 or 232 Network
on page
22.

32MLS, MLS332

Anafaze 32 Loop

8CLS, CLS208
4CLS, CLS204

Anafaze 8 Loop

32MLS (Anafaze protocol)

Anafaze/AB

1

Scan with the Watlow F4 Programmer driver only if the F4 programmer option is enabled.