Program mode quick reference – Watlow MINICHEF 2000 Rotisserie Oven Application User Manual
Page 6

4
■
Wa t l o w M
I N I
C
H E F
2 0 0 0
A p p l i c a t i o n 2 7
Program Mode Quick Reference
These are the functions, parameters and values included in the Program Mode for this
application. You must select Application 27 to access them.. For menu programming
directions, see the Hardware & Software Setup Guide. The Appendix of that guide
includes a detailed explanation of all parameters and values.
Function
Parameter
Value/Description
Your Settings
[M`__] Menu
[Stpt1] Set point 1
Temp range low
Numbers 1 - 30
Temperature of set point 1
to temp range high.
[TiNe1] Time 1
Setting both Time 1
Run time of set point 1.
and Time 2 to 0
invalidates selected menu.
Format varies based
on configuration.
[Stpt2] Set point 2
Temperature of set point 2.
Temp range low
to temp range high.
[TiNe2] Time 2
Setting both Time 1
Run time of set point 2.
and Time 2 to 0
invalidates selected menu.
Format varies based
on configuration.
[Hstpt] Hold Set point
Temp range low
Temperature at which
to temp range high.
the oven will operate
during hold sequence.
Auto-tuning Note:
Before auto-tuning Application 27 , the Set Point 1 of Menu 1 must first be set to a value
that is typical of your application (See the Hardware & Software Setup Guide for infor-
mation on programming menus.). Then set [tHerl] / [tunE1] to [```on]. After you
accept [```on], by pressing “Enter,” the controller will display [`tunE] while auto-tun-
ing is taking place.
The controller will cancel the auto-tuning process if it cannot be completed in 80 min-
utes. You can cancel the auto-tuning process at any time by pressing either key C or key
D and accepting [``Off], by pressing “Enter,” when it appears.