Proface APL3000B - Node Box PC User Manual
Page 80
Chapter 3 PS-A Monitoring Features
3-29
3.8.1
Voltage / Fan / Temperature / Backlight / DIN0 / DIN1
•
The Voltage, Fan, Temperature, Backlight and DIN1 tabs display the same setting items as the
DIN0 tab.
•
DIN1 tab cannot be set up when a checkmark is off in the [Enable] checkbox of Remote reset
tab. Remote reset feature, refer to the following section.
•
The FAN tab is not displayed on the PS-3651A.
•
The DIN0,1 tabs are not displayed on the PS3650A-T42S / PS3651A-T42S.
Item
Operation
Enable
When this option is checked, monitoring of the item starts.
Error Action
Specifies the action(s) taken when the System Monitor detects that the
allowable range is exceeded. You need to check [Enable] before you
can select actions.
LED
The front LED lights orange.
Buzzer
Sounds a beep as an alarm.
•
Cannot be set up when a checkmark is put in the “OS Shutdown” checkbox.
Pop-up
Message
When [PopupMessage] is specified as an action, the characters entered
in the field (e.g. DIN0 Error) are displayed as a popup message.
For the details about the PopupMessage feature, refer to the following section.
Error
Action
DOUT0 to 1
Output from the RAS port.
•
Nothing is displayed on the PS3650A-T42S / PS3651A-T42S.
OS Shutdown
Shuts down the operating system.
•
The shutdown confirmation message is not displayed.