General Specifications
2.1.1
Electrical
2.1.2
Environmental
PS-3650A/PS-3651A Series
AC Power Supply Type
(PS3650A-T42/
PS3651A-T42/
PS3650A-T42S/
PS3651A-T42S)
PS-3650A/PS-3651A Series
DC Power Supply Type
(PS3650A-T42-24V/
PS3651A-T42-24V/
PS3650A-T42S-24V/
PS3651A-T42S-24V)
Power
Supply
Input Voltage
AC100/240V
DC24V
Rated Voltage
AC85 to 265V
DC19.2 to 28.8V
Rated
Frequency
50/60Hz
-
Allowable
Voltage Drop
1 cycle or less (Voltage drop
interval must be 1s or more.)
5ms (max.)
Power
Consumption
PS-3650A Series:110VA or less
PS-3651A Series:95VA or less
PS-3650A Series:80W or less
PS-3651A Series:40W or less
In-Rush Current
AC100V (room temperature):
30A or less
AC240V (room temperature):
50A or less
30A or less
(room Temperature)
Voltage Endurance
AC1,500V 20mA for 1 minute
(between charging and FG
terminals)
AC1,000V 20mA for 1 minute
(between charging and FG
terminals)
Insulation Resistance
DC500V 10M
Ω(min.) (between charging and FG terminals)
PS-3650A Series
PS-3651A Series
Phy
s
ic
al
Surrounding Air
Temperature
0 to 50°C: without HDD
5 to 50°C: with HDD
0 to 50°C: without HDD
5 to 45°C: with HDD
Storage Temperature
-20 to +60°C
Ambient Humidity
10%RH to 90%RH
(Not condensing, wet bulb temperature: 39°C or less. Wet bulb
temperature with HDD: 29°C or less.)
Storage Humidity
10%RH to 90%RH
(Not condensing, wet bulb temperature: 39°C or less.)
Dust
0.1mg/m
3
and below (non-conductive levels)
Pollution Degree
For use in Pollution Degree 2 environment
Corrosive gas
Free of corrosive gas
Atmosphere
(Using height)
800 to 1,114hPa