Progressive International Electronics PIcon Console User Manual
Page 15

PIcon
Installation and Operation
Rev 2.0
June 2006
Page 11
The LEDs above each of the pump select keys are the status indicators for that particular
dispenser/fueling position. The green LED on the left indicates call/in use. The red LED on the
right indicates collect/stopped. Table: LED Indicators, below, shows the various states these
LEDs represent for each dispenser/fueling position.
GREEN LED
RED LED
STATUS
Fast Flash
—
Call for service
On Solid
—
Authorized
—
Slow Flash
Collect "A" Sale
—
On Solid
Dispenser Stopped
Fast Flash and
Fast Flash
Drive-Away
Slow Flash and
Slow Flash
Collect "A" and "B" Sales
Table: LED Indicators for Dispenser/Fueling Positions