Specifications: warnings, User’s responsibility for ce compliance – Ramsey Winch DC 34,9 User Manual
Page 4
* SPECIFICATIONS:
WARNINGS:
THE USER SHALL ENSURE THAT THE OPERATING PERSONNEL ARE GIVEN THE NECESSARY TRAINING.
THE OPERATOR SHALL ALWAYS WORK IN COMPLIANCE WITH THE OPERATING INSTRUCTIONS.
CLUTCH MUST BE FULLY ENGAGED BEFORE STARTING THE WINCH.
DO NOT DISENGAGE CLUTCH UNDER LOAD.
STAY OUT FROM UNDER AND AWAY FROM RAISED LOADS.
STAND CLEAR OF ROPE WHILE PULLING. DO NOT TRY TO GUIDE ROPE.
DO NOT USE WINCH TO LIFT, SUPPORT, OR OTHERWISE TRANSPORT PERSONNEL.
A MINIMUM OF 2 WRAPS OF ROPE AROUND THE DRUM BARREL IS NECESSARY TO HOLD THE LOAD.
AVOID CONDITIONS WHERE LOAD SHIFTS OR JERKS OCCUR. EXCESSIVE “INCHING” SHALL BE
AVOIDED.
User’s Responsibility for CE Compliance
1. Mount winch per Installation Instructions.
2. Install the emergency stop switch per Installation Instructions included with the Emergency Stop Switch Kit.
3. Install 10 mm (.393 in) grade 1960 wire rope. Maximum Rope length of 28 M (95 ft) for three layers maximum.
4. Attach rope to the drum per Rope Installation Instructions.
5. Use a hook which includes a safety latch and has a minimum breaking strength of 87 kN.
4
Ambient Temp Range
-28C to 60C (-20F to 140F)
Noise Level
80db
LAYER OF ROPE
1
2
3
Rated Line Pull Per Layer
kN
34,9
28,9
24,9
lb
7,840
6,500
5,600
Cummulative Rope Capacity Per Layer (Long
Drum)
m
7
16
28
ft
25
55
95
Cummulative Rope Capacity Per Layer (Short
Drum)
m
3
9
15
ft
10
30
50
Line Pull First Layer
kN
No Load
8,8
17,7
34,9
lb
2,000
4,000
7,840
* DC 34,9 & DCY 34,9 Line
Speed First Layer 12 V &
24V
MPM
4,3
2,1
1,5
1,7
FPM
14
7
5
3.5
*DC 34,9 & DCY 34,9 Amp
Draw
12V
65
110
180
370
24V
30
50
90
140
* These specifications are based on recommended 10 mm (.393”) 1960 grade wire rope.