* SPECIFICATIONS:

WARNINGS:

THE USER SHALL ENSURE THAT THE OPERATING PERSONNEL ARE GIVEN THE NECESSARY TRAINING.
THE OPERATOR SHALL ALWAYS WORK IN COMPLIANCE WITH THE OPERATING INSTRUCTIONS.
CLUTCH MUST BE FULLY ENGAGED BEFORE STARTING THE WINCH.
DO NOT DISENGAGE CLUTCH UNDER LOAD.
STAY OUT FROM UNDER AND AWAY FROM RAISED LOADS.
STAND CLEAR OF ROPE WHILE PULLING. DO NOT TRY TO GUIDE ROPE.
DO NOT USE WINCH TO LIFT, SUPPORT, OR OTHERWISE TRANSPORT PERSONNEL.
A MINIMUM OF 2 WRAPS OF ROPE AROUND THE DRUM BARREL IS NECESSARY TO HOLD THE LOAD.
AVOID CONDITIONS WHERE LOAD SHIFTS OR JERKS OCCUR. EXCESSIVE “INCHING” SHALL BE
AVOIDED.

User’s Responsibility for CE Compliance

1. Mount winch per Installation Instructions.
2. Install the emergency stop switch per Installation Instructions included with the Emergency Stop Switch Kit.
3. Install 10 mm (.393 in) grade 1960 wire rope. Maximum Rope length of 28 M (95 ft) for three layers maximum.
4. Attach rope to the drum per Rope Installation Instructions.
5. Use a hook which includes a safety latch and has a minimum breaking strength of 87 kN.

4

Ambient Temp Range

-28C to 60C (-20F to 140F)

Noise Level

80db

LAYER OF ROPE

1

2

3

Rated Line Pull Per Layer

kN

34,9

28,9

24,9

lb

7,840

6,500

5,600

Cummulative Rope Capacity Per Layer (Long

Drum)

m

7

16

28

ft

25

55

95

Cummulative Rope Capacity Per Layer (Short

Drum)

m

3

9

15

ft

10

30

50

Line Pull First Layer

kN

No Load

8,8

17,7

34,9

lb

2,000

4,000

7,840

* DC 34,9 & DCY 34,9 Line
Speed First Layer 12 V &
24V

MPM

4,3

2,1

1,5

1,7

FPM

14

7

5

3.5

*DC 34,9 & DCY 34,9 Amp
Draw

12V

65

110

180

370

24V

30

50

90

140