IEI Integration AFL2-15A-H61 User Manual
Page 81

AFL2-15A-H61
Page 64
Î
Disabled
Temperature of Fanless option can not be configured.
Î
Enabled D
EFAULT
Temperature of Fanless option can be configured.
Î Temperature Of Fanless [32 C]
NOTE:
If the Temperature of Fanless is enabled, the fan will only turn on when
the Environment Temperature 1 reaches to the temperature set in the
following Temperature of Fanless option.
For safety reason, the fan will turn on automatically to cool down the
system when the CPU temperature exceeds 80 ºC, no matter the
Temperature of Fanless is enabled or not.
Use the Temperature Of Fanless option to configure default temperature setting. When
the environment temperature is lower than default temperature setting, the fan will turn off.
When the environment temperature is higher than default temperature setting, the fan will
turn on. A list of available options is shown below:
Î
Disabled
Disabled the Temperature Of Fanless function
Î
4 C
When the environment temperature 1 is lower than 4 C,
the fan will be switched off.
Î
8 C
When the environment temperature 1 is lower than 8 C,
the fan will be switched off.
Î
12 C
When the environment temperature 1 is lower than 12
C, the fan will be switched off.
Î
16 C
When the environment temperature is lower than 16 C,
the fan will be switched off.
Î
20 C
When the environment temperature 1 is lower than 20
C, the fan will be switched off.