Ct-7000 operating instructions – Vanguard CT-7000 User Manual
Page 69
CT-7000 Operating Instructions
62
9.22 CT-7000 Channel Configuration
The CT-7000 is available with 3-, 6-, or 12- contact inputs. Under most common timing
conditions, the user needs to use only 3 contact timing channels and one travel transducer. There
is no need to print more than 3 timing channels and one transducer channel on the graphic and
tabulated report. The CT-7000 will always default to 3 contact channels (channel 1, 2 and 3) and
one transducer channel (transducer channel #1) when the user first turns on the unit. The user can
always turn on the rest of the timing channels and transducer channels by following the steps
shown in the table below:
Table 27.0 Channel Configuration
STEP
OPERATION
ACTION
DISPLAY
1
SELECT SET UP MENU.
PRESS # 3 KEY.
1. ANALYSIS POINT
2. MEASUREMENT UNITS
3. SAVE / RESTORE
4. NEXT PAGE
2
SELECT NEXT PAGE.
PRESS # 4 KEY.
1. SHOT DESCRIPTION
2. NUMBER OF CHANNELS
3. COMPUTER ITF
4. SET CLOCK 5. PRINT MODE
3
SELECT NUMBER OF CHANNELS.
PRESS # 2 KEY.
NUMBER OF CHANNELS
1. 3 CONTACT
2. 6 CONTACT
3. 12 CONTACT
4
SELECT 3 CHANNELS OR 6
CHANNELS OR 12 CHANNELS.
PRESS # 1, OR 2 OR
3 KEY.
1. TRANSDUCER 1
2. TRANSDUCER 1 & 2
3. TRANSDUCER 1 & 2 & 3
5
SELECT 1 TRANSDUCER, OR 2, OR 3.
PRESS #1, OR #2, OR
#3.
1. TIME BREAKER
2. GET RESULT
3. SET UP
4. DIAGNOSTIC