beautypg.com

Teledyne LeCroy WaveStation SCPI Command Reference Manual User Manual

Page 18

background image

WaveStation SCPI

Parameters

Value

Description

MEAN

Parameter is valid only when WVTP is NOISE. Where := {default unit is

V; range depends on }.

WIDTH

Value of width. Parameter is valid only when WVTP is PULSE.

RISE

Value of rise. Parameter is valid only when WVTP is PULSE.

FALL

Value of fall. Parameter is valid only when WVTP is PULSE.

DLY

Where := {default unit is S; minimum 0, maximum is Pulse Period}.

Parameter is valid only when WVTP is PULSE.

QUERY SYNTAX

:BaSicWaVe?

:=

{C1|C2}

RESPONSE

:BSWV ,,,,,

,

EXAMPLE 1

Set Channel 1 basic wave type to Ramp.

C1:BSWV WVTP,RAMP

EXAMPLE 2

Set Channel 1 signal frequency to 2000Hz.

C1:BSWV FRQ,2000HZ

EXAMPLE 3

Retrieve Channel 1 Basic Wave settings.

C1:BSWV?

Return:

C1:BSWV TYPE,SINE,FRQ,1000,AMP,3,OFST,3

RELATED

ARWV, BTWV, CFG, CPL, MDWV, SWWV

16

922829 Rev C