6. Inspection/Maintenance
6.3 Battery
Replacement
6.3.1 Preparation
The following items are required when replacing the batteries:
Phillips screwdriver
New dedicated batteries for IX: AB-3 (4 pieces)
Before replacing the batteries, turn off the power to the controller, control panel and other relevant units.
Performing inspection or maintenance without fully understanding the details of work may result in
a serious accident.
Display a “Work in Progress” sign so that other operators will not operate the controller, operation
panel, etc.
Use dedicated batteries for IX. Batteries for the old model (IH) cannot be used.
Warning