(5) E0 - E3 programming errors Group 4/Command error - 3
These errors, like those in sections 3 and 4 above, primarily arise from the way the commands are used.
(6) EG error - Emergency Stop
If an EG alarm occurs, consider the following.
Q Emergency stop signal asserted
Determine what triggered the emergency stop and then release the emergency stop (press the button). During an
emergency stop, the ready signal or output 301 is OFF and the alarm or output 300 is ON. However, if the emergency
stop is asserted when the power is turned ON, alarm output 300 will not go ON. The 300 output functions after the
ready signal is given.
E0
Undefined command error
Attempted to execute an
use the PC interface softw
prevent this.
E1
Subroutine overnesting error
There are more than 15 s
alarm occurs after trying t
program so that the numb
less than 15. Also note th
use of the IF command, th
error.
E2
Subroutine under nesting error
BGSR is not paired with E
found before the EDSR.
E3
Controlling column error
The expansion condition i
using the PC software, it w
syntax error at the time of
Power ON
Emergency stop
Ready signal (301)
Alarm output (300)