IAI America RCS2-TFA5N User Manual
Page 47

10. Maintenance and Inspection
41
[Internal inspection of guide rail]
Turn off the power and pull out the table.
If the lead is too small to move the table, insert a screwdriver, etc., into the cutout groove provided in the shaft on
the rear side and turn. [Refer to “How to Move Table by Hand.”]
Visually check the table and actuator’s guide rail for lubrication condition.
Even when the grease is brown, the screw is lubricated property as long as the traveling surface looks wet and
shining. If the grease is mixed with dust and dirty or has no shiny appearance, or if the grease has
lost its efficacy due to prolonged use, clean the applicable area and then replenish the grease.
Actuator
Table
Table
Guide rail V-groove (2 locations)
Actuator
Guide rail V-groove (2 locations)
Front
Rear